Leave Your Message
Standard Container Energy Storage – 314Ah Immersion-Cooled for Grid & C&I
Energy Storage System
Products Categories
Featured Products

Standard Container Energy Storage – 314Ah Immersion-Cooled for Grid & C&I

314Ah large-format immersion-cooled container energy storage. Cells fully submerged in coolant – no fire, no explosion, no smoke even under thermal runaway. 4S+C full-stack self-developed (BMS+PCS+EMS+TMS+Cloud) . For grid-scale, C&I, data centers, oil fields & mines.

    Core Selling Points

    The Standard Container Energy Storage System is engineered with the latest 314Ah high-capacity storage cells, achieving an optimal balance of safety, economy, and compactness. In this system, battery cells are directly immersed in coolant, completely isolating them from air and moisture – eliminating any possibility of battery combustion or explosion. Even under thermal runaway conditions, the system will not catch fire, not explode, and not emit smoke. The product and solution can be flexibly customized to meet specific user requirements. This is the next-generation safety-first energy storage solution for grid-scale and commercial applications.
    • AN0A1035
    • AN0A1047

    Application Scenarios

    The Standard Container Energy Storage System is suitable for a wide range of demanding applications:
    Scenario Description
    Medium-to-Large Grid-Side Storage Power Stations Utility-scale energy storage for grid stabilization, peak shaving, and renewable integration
    Commercial & Industrial (C&I) Storage Factories, commercial buildings, and industrial parks
    High-Temperature Environments Deserts, tropical regions, and industrial settings with extreme heat
    Low-Temperature / Cold Climates Alpine regions, cold deserts, and northern latitudes
    Data Centers / Server Rooms Facilities requiring absolute fire safety and uninterrupted operation
    Oil Fields Remote extraction sites with high safety requirements
    Mines / Underground Facilities Explosive-prone environments demanding fail-safe energy storage

    Technical Advantages

    1. 4S+C Full-Stack Self-Development
    Through vertical integration of four core hardware components and the cloud platform – BMS (Battery Management System) , PCS (Power Conversion System) , EMS (Energy Management System) , TMS (Thermal Management System) , and Cloud – we have established a full-chain data loop from cell to cloud. This achieves integrated design, integrated control, and integrated optimization, precisely solving the industry's "impossible triangle" of balancing safety, cost, and performance.

    2. Full-Immersion Liquid Cooling Technology
    In the full-immersion liquid cooling energy storage system, battery cells are directly submerged in coolant, completely isolating them from air and moisture – completely eliminating the possibility of battery combustion or explosion.
    Even under thermal runaway conditions, the system will not catch fire, not explode, and not emit smoke – a paradigm shift in battery safety.
    Effectively controls the operating temperature of the battery storage system, enabling fast, uniform, and thorough cooling of cells, ensuring long-term stable operation across extreme temperature ranges.

    3. Full Lifecycle Active Maintenance
    Full lifecycle active maintenance refers to systematic management and care throughout the entire service life of the energy storage system – from commissioning to decommissioning. This approach ensures the safety, efficiency, and stable operation of the system over its entire lifespan, minimizing downtime and reducing total cost of ownership.

    Design, Safety & Intelligence

    314Ah High-Capacity Cell – Optimized Architecture
    The system is built around the latest 314Ah large-format prismatic cells, specifically selected for their energy density, cycle life, and thermal stability. The containerized architecture is optimized for structural compactness, reducing footprint while maximizing energy capacity.

    Full-Immersion Cooling – How It Works
    Unlike traditional liquid-cooled systems where coolant circulates through cold plates, full-immersion cooling places the cells directly in a dielectric coolant. This eliminates any air gap between the cell and the cooling medium, resulting in:
    ● Faster heat extraction – No thermal interface resistance
    ● Uniform cell temperature – No hot spots across the cell surface
    ● Complete environmental isolation – No oxygen, no moisture, no dust – no fire risk

    Thermal Runaway Containment – Absolute Safety
    In the rare event of a cell failure, the coolant itself acts as a thermal barrier. Because the cell is already submerged in a non-flammable dielectric fluid:
    ● No oxygen reaches the cell – no combustion possible
    ● Heat is rapidly dissipated into the coolant – no thermal propagation to adjacent cells
    ● No smoke or toxic gas emission – safe for indoor and personnel-intensive environments

    4S+C Cloud Platform – Full Visibility & Control
    The integrated cloud platform provides:
    ● Real-time monitoring of every cell's voltage, temperature, and state of charge
    ● Predictive maintenance alerts based on AI-driven anomaly detection
    ● Remote firmware updates (OTA) for BMS, PCS, and EMS
    ● Data visualization dashboards for operators and asset managers

    Customization Options
    The system can be flexibly customized based on:
    ● Capacity requirements (MWh scale)
    ● Voltage and power configurations
    ● Communication protocols (CAN, RS485, Modbus, IEC 61850)
    ● Environmental adaptations (IP rating, heating/cooling, seismic rating)

    Why Choose Our Standard Container Energy Storage?

    Safety is the #1 concern for grid-scale and commercial energy storage. Lithium-ion battery fires have made headlines worldwide, creating hesitation among investors, insurers, and regulators. Our Standard Container Energy Storage System eliminates this risk entirely through full-immersion liquid cooling technology.

    For grid operators: Deploy energy storage for frequency regulation, peak shaving, and renewable firming – without the fire risk that has plagued the industry. Our system meets the highest safety standards, simplifying permitting and insurance approval.

    For commercial & industrial facilities: Install storage behind-the-meter to reduce demand charges and arbitrage time-of-use rates – even in sensitive environments like data centers, oil fields, and mines where fire is simply not an option.

    For extreme environments: Whether you are operating in the high heat of the Middle East or the freezing cold of Northern Europe, the immersion cooling system maintains optimal cell temperature year-round – something air-cooled and even traditional liquid-cooled systems struggle to achieve.

    For project developers: The 4S+C full-stack self-developed architecture means single-vendor accountability, seamless integration, and remote monitoring via cloud. No more finger-pointing between BMS, PCS, and EMS suppliers.

    With 314Ah high-capacity cells, full-immersion liquid cooling, thermal runaway containment (no fire, no explosion, no smoke) , full lifecycle active maintenance, and flexible customization, this container energy storage system delivers the safety, reliability, and peace of mind that the industry has been waiting for.

    Product Parameters

    Parameters

    Description

    Battery Type Lithium Iron Phosphate (LiFePO₄)
    Cell Specification 314Ah
    Battery Pack Specification 1P60S
    Battery Rack Specification 12*PACK7 Configuration
    DC Side Nominal Voltage 1331.2V
    Nominal Energy 5064kWh
    DC Side Operating Voltage Range 1176~1491V
    Charge Cut-off Voltage 3.55V per cell
    Discharge Cut-off Voltage 2.8V per cell
    Depth of Discharge (DoD) 90%
    Rated Current Rack Rated Current
    Fire Protection System Submerged Liquid Cooling + Active Early Warning
    Operating Ambient Humidity 0%~95%(non-condensing)
    Operating Ambient Temperature -30℃~50℃
    Ingress Protection (IP) Rating IP54
    Cooling Method Submerged Liquid Cooling
    Storage Requirements Store at 35% SOC or cell voltage of 3.285V~3.305V
    Product Communication Method Ethernet communication, supports CAN bus, IEC60870-5-103, IEC61850/TCP, Modbus/TCP and other protocols
    BMS Three-tier Battery Management System, includes high-voltage box
    Weight 40T
    Cabinet Dimensions (WDH) 6637x3000x3000mm
    Operating Altitude ≤2000m

    PBMS-48100-5PBMS-48100-2company
    Request A Quote
    Need a Consultation? Contact Us 24/7
    Describe your specific request*
    bg-contact